0U metered input ePDU, 3-phase 63A IEC 309 input
18x C13 and 12x C19 outlets, rack-mounted
The Eaton ePDU G3+ Metered Input 0U is a zero-U, three-phase power distribution unit built for data centres, server rooms and network cabinets that need a dependable, clearly metered power supply. Eaton’s ePDU G3+ family is designed to distribute power to the equipment in a rack while giving the operator visibility of the power being used. This particular model, listed as EPDU MI 0U, is the metered input version with a 63A three-phase input and a total of thirty outlets.
Zero-U means the unit mounts vertically in the side of the rack rather than occupying one of the rack units used for active equipment. This keeps the usable height of the cabinet free for servers, switches, storage arrays and patch panels, while the power outlets run along the full height of the cabinet where the equipment is connected.
A metered input unit shows how much power the rack draws from the supply. In practice, this helps the facilities team see whether a cabinet is approaching the limit of its supply, spot unexpected increases in load, and check that the three phases are reasonably balanced. Balanced phases reduce stress on the supply and make it easier to add equipment later without overloading one leg of the circuit.
Metering at the input is different from metering each outlet or outlet group. It gives an overall picture of the rack, which is often what is needed for capacity planning, budgeting power for new hardware, and deciding when a cabinet needs an additional supply. Where more detailed control is required, other ePDU G3+ variants in the range may be a better fit.
The eighteen C13 outlets suit the most common server, switch and storage power supplies. The twelve C19 outlets are for equipment with higher power demand, such as larger servers, storage controllers and some network platforms. Having both types on one unit means a single ePDU can power a mixed rack without adaptors. Outlets are distributed along the unit, so cables can run neatly from each device to the nearest outlet.
The unit connects to a 63A three-phase supply through an IEC 309 industrial plug, so it should be installed by a qualified electrician who can confirm that the supply, circuit protection and cabling are suitable. Check the rack depth and mounting space before ordering, and confirm that the outlet count and connector types match the equipment that will be installed.
This product is brought in on request only and orders are irrevocable. Please confirm stock and lead time with the sales team before placing an order, and make sure the configuration is exactly what is needed, as the order cannot be cancelled once placed.
In short, the Eaton ePDU G3+ Metered Input 0U 63A 3-Phase is a practical choice for racks that need a robust three-phase power feed, a generous mix of C13 and C19 outlets, and clear metering of the total power drawn.