Rack PDU G4 Switched, 0U, 32A single phase
12 x C13 and 12 x C19 outlets, brought in on request
The Eaton Rack PDU G4 Switched EVSWF132A is a vertical power distribution unit designed to deliver power to the equipment in a server or network rack. Instead of running many separate cords from a wall socket, the rack PDU takes one heavy supply and distributes it to multiple outlets inside the cabinet. The result is neater cabling, better organisation and easier management of the devices that depend on it.
This model is rated for a single phase 32A supply and provides twelve C13 outlets and twelve C19 outlets. The C13 outlets suit standard server power leads and many switches and small appliances, while the C19 outlets are the higher-current connectors typically used by larger servers, storage arrays and blade chassis. Together, the twelve-plus-twelve layout gives a good number of connection points for a typical rack population.
A switched rack PDU adds control to the power distribution. Each outlet can be switched on or off independently, which allows an administrator to power-cycle a hung server, sequence the start-up of equipment after a power outage, or isolate a single device for service while the rest of the rack keeps running. For facilities that need to keep systems available, this kind of granular control reduces the need for physical access to the cabinet.
This unit is suited to data centres, server rooms, comms rooms and network cabinets where a dependable, manageable power supply is needed for many devices at once. It can serve as the main distribution point for a rack of servers, storage and switching equipment, and it is well suited to environments where remote switching of individual outlets saves time and reduces risk.
Eaton ePDUs are not kept as regular stock and are brought in on request only. Orders are irrevocable once placed, so please confirm the exact model, outlet configuration and supply requirements before ordering. Because the product is ordered in specifically for each customer, lead times depend on the supplier.
When planning a rack installation, check that the electrical supply and circuit protection at the site match the 32A single phase rating, and that the outlet types suit the devices you intend to connect. A qualified electrician should carry out the connection to the supply.