FlexPDU G2 Switched 0U C20 1P 16A 20xC13 4xC19

Eaton
0U zero-U switched PDU, single-phase 16A, C20 inlet
20 x C13 and 4 x C19 outlets

SKU FLXTSWC20C2 Category Brand:
Share

Eaton FlexPDU G2 Switched 0U C20 1P 16A, 20xC13 and 4xC19 Outlets

The Eaton FlexPDU G2 Switched is a zero-U power distribution unit built to bring a reliable, organised power supply to the IT equipment inside a rack cabinet. The model number describes the key features: FlexPDU G2 is the second generation of Eaton’s flexible PDU range, Switched refers to the switchable outlet design, 0U means the unit mounts vertically without using rack space, C20 is the inlet connector, 1P means single-phase supply, 16A is the current rating, and the outlet mix is twenty C13 and four C19 connectors.

Power distribution inside a cabinet can quickly become messy. Many servers, switches, storage units and routers each need their own power lead, and without a proper distribution unit these leads end up in a tangle at the back of the rack. A zero-U PDU such as this one solves that problem by mounting along the side or back of the cabinet, leaving the rack units free for active equipment and keeping cables neatly routed.

Key features and specifications

  • Product family: Eaton FlexPDU G2 Switched
  • Mounting: 0U zero rack unit, vertical mount in the cabinet
  • Supply type: single-phase (1P)
  • Current rating: 16A
  • Inlet connector: C20
  • Outlets: 20 x C13 and 4 x C19
  • Outlet type: switched, as per the FlexPDU G2 Switched model range

Why choose a switched PDU

A switched PDU gives you control over the power going to individual outlets. In practice this means that a device connected to one outlet can be switched off, switched on or restarted without affecting the other equipment on the unit. This is useful when a server has locked up and needs a power cycle, when a piece of equipment should be isolated for maintenance, or when power sequencing is needed during a planned shutdown or start-up of the rack.

Compared with an unswitched or basic PDU, the switched design adds this level of outlet-by-outlet control. It is best suited to environments where a site manager or network administrator wants to manage power remotely rather than walking to the cabinet each time a device needs attention.

Outlet layout and connections

The twenty C13 outlets are the standard connector used by most desktop computers, servers, switches, monitors and small network devices. The four C19 outlets are designed for higher-power equipment, such as larger servers, blade chassis and some storage arrays, which commonly use C19 power leads. Having both outlet types on one unit means that a single PDU can serve most of the equipment in a typical rack, rather than needing separate units for each connector type.

Typical uses

This PDU suits a range of environments where many devices share a single cabinet. Common applications include:

  • Server rooms and comms rooms in offices, schools and clinics
  • Data centre racks where tidy, zero-U power distribution is required
  • Network cabinets that house switches, routers, firewalls and patch panels
  • Edge computing and branch-office installations
  • Any rack where remote power control of individual devices is useful

Installation and planning

Before installing the unit, check that the cabinet has suitable space at the side or back for vertical mounting and that the supply point matches the 16A single-phase C20 inlet. Plan the cable routing so that the inlet lead reaches the supply without strain, and keep the equipment power leads organised along the PDU. Good planning at this stage makes future changes and maintenance much easier.

Ordering information

The FlexPDU G2 Switched is a special order item and is brought in on request. Orders are irrevocable once placed, so please confirm the exact model, outlet configuration and power requirements with the sales team before ordering. This helps ensure the unit matches your rack layout and the equipment it will supply.

SKU FLXTSWC20C2 Category Brand:

Eaton
FlexPDU G2 Switched 0U C20 1P 16A 20xC13 4xC19

Eaton
0U zero-U switched PDU, single-phase 16A, C20 inlet
20 x C13 and 4 x C19 outlets

Share this on your favourite channel:

Sign Up & Register

Mustek’s Infrastructure Technology Team are one of the largest suppliers of infrastructure technology in the country and on the continent. Register to become a reseller. Already a reseller?

Sign up for the latest pricelists, specials and offers.

Are you registered as a reseller?*
Area of interest?*

UPS Q&A

Keep up to date with the latest product developments from our divisions and outstanding solutions that will inspire you.

UPS Configuration Questionnaire

Ready to talk