INFRASTRUCTURE TEAM
+27 (0) 11 237 1000
Eaton
Rack PDU G4 Metered Input, 0U zero-U mounting
C20 inlet, 16A, single phase, 12x C13 and 12x C39 outlets
The Eaton Rack PDU G4 MI 0U C20 16A 1P 12xC13,12xC39 is a rack-mounted power distribution unit (PDU) from Eaton’s G4 range, built to deliver power reliably to a dense group of IT devices inside a cabinet. Its metered-input design gives you visibility of the load coming into the unit, while its twelve C13 and twelve C39 outlets provide plenty of connection points from one feed.
Power distribution is often an afterthought until a rack runs out of outlets or a circuit becomes overloaded. A well-chosen PDU solves both problems. This unit brings a single C20 16A single-phase supply into the cabinet and divides it across twenty-four outlets, so servers, switches, storage arrays and other equipment can be connected in an orderly way without daisy-chaining power strips.
The model code breaks down into several parts. PDU means power distribution unit. G4 identifies the generation of the product line. MI stands for metered input, meaning the input current and power are measured. 0U means zero rack units, so the unit does not occupy a full unit of cabinet height. C20 is the input connector type, the single-phase 16A inlet that feeds the unit. 1P means single phase. The outlets are listed as twelve C13 and twelve C39, which are standard IEC 60320 connector types used widely on IT and networking equipment.
A metered input lets you see the total load the PDU is drawing from the supply circuit. This is valuable when several cabinets share a feed, when equipment is added over time, or when you need to make sure a circuit stays within its safe working limit. Knowing the load in advance helps you avoid nuisance tripping, plan expansion and document power use for maintenance records. Metering the input at the PDU is simpler than estimating demand from equipment nameplates, which often list maximum rather than typical draw.
This unit suits a wide range of environments where many devices must be powered from one cabinet feed. Common uses include:
Before installing, confirm that the site can supply a single-phase 16A circuit with the correct C20 connection, or arrange the appropriate feed with a qualified electrician. Check that the C13 and C39 outlets match the plugs on your equipment, and use suitable power cords. Allow for the total load of connected devices, keeping in mind that the metered input will show you the real figure once the unit is in service. Measure the cabinet depth and mounting points to make sure the unit sits correctly beside your hardware, and leave room for cable routing so that airflow is not restricted.
If you need more or fewer outlets, a different inlet rating, a different outlet mix or a non-metered version, compare the options within the Eaton G4 range before ordering. Matching the PDU to your current equipment and expected growth will save time and rework later. Because this model is a specific configuration, verify each code carefully against your requirements.
In short, the Eaton Rack PDU G4 MI 0U C20 16A 1P 12xC13,12xC39 offers a practical blend of outlet capacity, rack efficiency and load visibility for IT and network environments that need dependable power distribution from a single 16A single-phase feed.
Eaton
Rack PDU G4 Metered Input, 0U zero-U mounting
C20 inlet, 16A, single phase, 12x C13 and 12x C39 outlets
Share this on your favourite channel: