AP6038.PER.B 38U 600×1000 Perforated Door Cabinet

MECER
38U 19 inch black floor-standing network cabinet, 600 x 1000 mm, perforated door
Max load 650 kg, includes 4 uprights and 4 feet

MECER AP6038.PER.B 38U 600×1000 Perforated Door Floor-Standing Network Cabinet

The MECER AP6038.PER.B is a 38U floor-standing 19 inch network and server cabinet in a black finish. It is built for businesses and institutions that need a dependable, well-organised home for active network and server equipment. With a 600 mm wide and 1000 mm deep footprint and a perforated front door, it combines a practical size with good airflow for everyday IT use.

In this model, the U in 38U refers to rack units. One rack unit is a standard height measurement of 44.45 mm, so 38U gives a large vertical mounting space that can take many devices at once. The cabinet is designed for 19 inch equipment, which is the standard width used by most switches, routers, servers, patch panels and power distribution units.

Key features and specifications

  • Height: 38U (38 rack units) for 19 inch equipment
  • Width: 600 mm
  • Depth: 1000 mm
  • Front door: perforated, for airflow
  • Finish: black
  • Maximum load rating: 650 kg
  • Supplied with: 4 uprights and 4 feet
  • Includes cable glands
  • Model code: AP6038.PER.B

Why the perforated door matters

Network and server equipment produces heat, and a closed cabinet can trap that heat and shorten the life of components. The perforated door lets air pass through the front of the cabinet, which supports the flow of cooler air over equipment. For a cabinet that houses switches, servers or storage, this is one of the most useful features to consider when choosing a front door style.

A perforated door is generally suited to rooms where security is controlled by the building itself, such as a locked server room or a comms cupboard. If the cabinet sits in a more public area, a glass door may be preferred for a different look, although it offers less airflow than a perforated panel.

Load capacity and stability

The rated maximum load of 650 kg makes this cabinet suitable for a full rack of equipment, including heavier devices and multiple units stacked in the cabinet. Before loading, it is sensible to check the weight of each item and to fill the cabinet from the bottom up, so the centre of gravity stays low and the cabinet remains stable.

Included parts

The package includes four uprights, which are the vertical mounting rails that hold equipment, and four feet, which allow the cabinet to stand firmly on the floor. Cable glands are also supplied, giving neat entry points for cables into the cabinet so they can be routed without clutter.

Typical uses

  • Housing network switches, routers and firewalls
  • Storing servers and network-attached storage
  • Organising structured cabling and patch panels
  • Protecting IT equipment from dust and accidental contact
  • Creating a tidy, managed comms room or server room

Because the cabinet is floor-standing, it is well suited to larger installations where a wall-mount unit would not provide enough space. Several cabinets of the same size can also be placed side by side to create a consistent row of equipment.

Planning your installation

When planning the installation, allow enough space at the front and rear for access to equipment and cabling. Route cables through the glands and use cable management to keep runs tidy, which makes future changes much easier. Make sure the floor is level so the feet sit evenly and the cabinet does not rock under load.

Keep the cabinet in a dry area with adequate ventilation. Good airflow helps the equipment inside run at a stable temperature, and the perforated door supports this. Where several units generate heat, consider additional cooling to maintain a safe operating environment.

Summary

The MECER AP6038.PER.B offers 38U of 19 inch mounting space in a 600 x 1000 mm black floor-standing cabinet with a perforated door, a 650 kg maximum load rating and the uprights, feet and glands needed to get started. It is a practical choice for anyone who needs a sturdy, well-ventilated home for network and server equipment.

MECER
AP6038.PER.B 38U 600×1000 Perforated Door Cabinet

MECER
38U 19 inch black floor-standing network cabinet, 600 x 1000 mm, perforated door
Max load 650 kg, includes 4 uprights and 4 feet

Share this on your favourite channel:

Sign Up & Register

Mustek’s Infrastructure Technology Team are one of the largest suppliers of infrastructure technology in the country and on the continent. Register to become a reseller. Already a reseller?

Sign up for the latest pricelists, specials and offers.

Are you registered as a reseller?*
Area of interest?*

UPS Q&A

Keep up to date with the latest product developments from our divisions and outstanding solutions that will inspire you.

UPS Configuration Questionnaire

Ready to talk