ATL 47U 600 x 1200 Perforated Door Network Cabinet

MECER
47U, 600 x 1200 mm, perforated door, black
Article ATL6247.PER.B

MECER ATL 47U 600 x 1200 Perforated Door Network Cabinet

The MECER ATL6247.PER.B is a 47U floor-standing 19-inch cabinet designed to house network, server and data equipment in a neat, protected enclosure. It belongs to the ATL high-density range from MECER, which covers cabinets in 42U and 47U heights, in 600 or 800 mm widths and 1000 or 1200 mm depths. This model is the 47U, 600 mm wide, 1200 mm deep version with a perforated front door and a black finish.

The ‘U’ in the name refers to rack units, the standard height measure for 19-inch equipment. Forty-seven rack units give you a large mounting area, so you can fit several switches, servers, patch panels, power distribution units and a UPS in one cabinet while still leaving space for cable management.

Key features

  • 47U rack height for a large amount of mounted equipment
  • 600 mm wide and 1200 mm deep, giving room for deeper servers and rear cabling
  • Perforated front door for airflow through the cabinet
  • Black finish for a clean, professional appearance
  • 19-inch mounting rails for standard rack-mount equipment
  • Supplied with four uprights, four feet, gland plates and screws

Airflow and equipment protection

Equipment in a closed cabinet generates heat, and that heat needs somewhere to go. The perforated door is designed to let air pass through the front, which supports the cooling of active equipment. Good airflow helps keep switches and servers within their operating temperature range, and it reduces the risk of heat-related faults. Blanking panels in unused rack spaces will help direct air correctly through the cabinet.

Cable management and layout

Cabling is one of the main challenges in a network cabinet. The 1200 mm depth gives room behind the mounting rails for power and data cables to be routed neatly. Keeping cables tidy makes maintenance easier, reduces accidental disconnections and makes it simpler to trace faults. Mount heavier equipment low in the cabinet and lighter patch panels higher up to keep the cabinet stable and easy to work in.

Assembly and supplied parts

The cabinet arrives with four uprights, four feet, gland plates and the screws needed for assembly. Gland plates are used at the top or bottom to bring cables into the cabinet in an organised way. Allow enough space around the cabinet for assembly and for opening the door fully. Check the specification sheet from MECER for the exact load rating and mounting details before installation.

Typical uses

  • Core and distribution switches in office networks
  • Server rooms in schools, clinics and small businesses
  • Storage and backup equipment
  • Housing UPS units and power distribution
  • Patch panel and structured cabling termination points

In each of these settings, the cabinet gives equipment a secure and organised home. A lockable door option, where supplied, can help restrict access to sensitive hardware. The perforated door suits environments where ventilation is important and where equipment runs continuously.

Choosing the right size

A 47U cabinet is a good choice when you expect to add equipment over time. Measure your current equipment and plan for future growth before choosing a height and depth. The 1200 mm depth suits deeper servers and storage devices, while shallower equipment will sit comfortably inside it. If you need a cabinet with a glass door instead, MECER also supplies glass-door versions in the same range.

Before purchase, confirm the exact specifications, load rating and included accessories with your supplier, as these details can vary between models in the range.

MECER
ATL 47U 600 x 1200 Perforated Door Network Cabinet

MECER
47U, 600 x 1200 mm, perforated door, black
Article ATL6247.PER.B

Share this on your favourite channel:

Sign Up & Register

Mustek’s Infrastructure Technology Team are one of the largest suppliers of infrastructure technology in the country and on the continent. Register to become a reseller. Already a reseller?

Sign up for the latest pricelists, specials and offers.

Are you registered as a reseller?*
Area of interest?*

UPS Q&A

Keep up to date with the latest product developments from our divisions and outstanding solutions that will inspire you.

UPS Configuration Questionnaire

Ready to talk