MECER
47U, 800 x 1200 mm, black, perforated door
Includes 4 uprights, 4 feet, gland plates and screws
The MECER ATL 47U 800 x 1200 Perforated Door Black Network Cabinet is a robust 19-inch floor-standing cabinet designed to house servers, network switches, patch panels and related IT equipment. It belongs to the MECER ATL high-density range, a series built for demanding server and data-centre environments where space, airflow and load capacity all matter.
With 47 rack units of usable height, this cabinet gives plenty of vertical space for a mixed rack of equipment. The 800 mm width gives standard rack space for most 19-inch devices, and the 1200 mm depth accommodates deeper servers and leaves room at the rear for power leads and data cabling.
The listing covers the main parts needed to build the cabinet: four uprights, four feet, gland plates and the screws to fix them together. Gland plates provide neat entry points for power and data cables, which helps prevent loose cabling from blocking doors or disturbing equipment.
A perforated door is designed to let air pass through the front of the cabinet. This matters when equipment produces heat, because steady airflow helps keep servers and switches within their operating temperature. Perforated doors are a common choice in server rooms where ventilation is planned as part of the overall cooling design. If privacy or dust protection is the priority, a glass door version from the same range may suit better.
The 47U height and 1200 mm depth make this cabinet suitable for deeper rack equipment and for installations where cable management at the rear is important. Plan the layout before installation: allow space around the cabinet for airflow, access and maintenance, and confirm that equipment depth and rear cable routes fit within the 1200 mm depth.
The ATL range is positioned as a high-density cabinet for heavy server and data-centre loads. Check the load rating in the product documentation for your specific installation, especially when fitting heavy UPS units or dense server stacks. Ensure the floor can take the combined weight of the cabinet and the equipment inside it.
Assemble the cabinet on a level floor and fix the feet securely. Use the gland plates to route cables cleanly from the top or bottom. Leave slack in cable runs so that equipment can be pulled forward for servicing, and label cables at both ends to make future changes easier. Keep the perforated door clear of obstructions so that air can flow freely.
This cabinet is listed as a black MECER ATL model in the 800 x 1200 mm size with a perforated door. If you need accessories such as shelves, fans, cable managers or additional mounting hardware, check compatibility with your sales representative before ordering, as these are not included in this listing.
Choose the MECER ATL 47U 800 x 1200 Perforated Door Black Network Cabinet when you need a sturdy, well-ventilated rack with generous height and depth for servers and network equipment in a business or data environment.