Lenovo South Africa Channel Awards 2
Lenovo South Africa Channel Awards
Congratulations to our Server Team. Distributor of The Year!
ThinkSystem Tower Servers
Modernize to boost your business with Windows Server 2022.
Think Big. Think Lenovo. ThinkSystem Tower Servers.
Lenovo F1

INFRASTRUCTURE TEAM

+27 (0) 11 237 1000

INFRASTRUCTURE TEAM

MOLEX
OSP PE Single Jacket Armour Gel 96F

Molex
OSP PE single jacket armoured singlemode fibre cable, 96 fibres
Outside plant fibre backbone and campus links

SKU CFR-00900 Category Brand:
Share

Molex OSP PE Single Jacket Armour Gel 96F: 96-Fibre Singlemode Outside Plant Cable

The Molex OSP PE Single Jacket Armour Gel 96F is a singlemode fibre optic cable designed for outside plant (OSP) use. It forms part of the Molex single-sheath singlemode cable offering and is supplied as a 96-fibre cable. Its construction combines a polyethylene jacket, an armour layer and gel filling, so it is suited to fibre links that have to survive outdoor conditions as well as the normal wear of a building backbone.

Fibre backbones are the arteries of a modern network. They carry traffic between buildings, between network rooms and between sites, and they are expected to run for many years without frequent maintenance. A cable of this kind is chosen when the route is longer, the environment is less controlled, or the fibre count needs to be high enough to serve many links from a single trench or duct.

Key features

  • Singlemode optical fibre, suited to long-distance links
  • 96 fibres in one cable for high-capacity backbones
  • OSP (outside plant) rated construction, as described by the supplier
  • PE (polyethylene) outer jacket
  • Single jacket construction with one outer sheath
  • Armoured for added mechanical protection
  • Gel-filled to help keep moisture away from the fibres
  • Part of the Molex CST single-sheath singlemode cable range

Why singlemode for outside plant

Singlemode fibre has a very small core, so light travels along one main path. This keeps signal loss low over long distances and supports high bandwidth for future upgrades. For campus or inter-building links, singlemode is the common choice because it can cover distances far beyond the reach of multimode fibre, and the same cable can carry several generations of transceivers over its life.

Why armour and gel matter

Outdoor and underground routes expose cable to moisture, temperature changes, soil movement, and occasional mechanical stress during installation. A PE jacket resists weathering and abrasion. The armour layer adds crush resistance during pulling and backfilling and can help against rodent attack. Gel filling fills the spaces between fibres and the loose tube, which helps prevent water from travelling along the cable if the jacket is damaged. These features are the reason armoured gel cables are specified for ducts, direct burial and aerial spans where an indoor cable would not last.

Typical uses

  • Backbone links between buildings on a campus or business park
  • Duct and direct-buried routes for estates and industrial sites
  • Feeder cables between a main equipment room and remote network rooms
  • Data centre and telecom site interconnects
  • Aggregation of many fibre links at a central distribution point

Installation and termination

At each end the cable is usually terminated in a splice box, fibre panel or enclosure. Individual fibres are spliced or connected to pigtails and then to patch leads, which run to the active network equipment. Mid-couplers and fibre panels allow the link to be patched and tested without disturbing the main cable. The cable should be handled within its specified bend radius and pulled within the tension limits set by the manufacturer. Installers should check the Molex datasheet for the full mechanical and optical data before they begin.

Ordering and planning notes

Before ordering, confirm the required length with a margin for slack, splicing and any route changes. Make sure the termination hardware matches the fibre type and connector choice on the active equipment. Plan for testing after installation, typically an optical loss test and an OTDR trace, and keep the results with the project documentation. Because outside plant work often involves excavation and permits, it is worth coordinating with the civil contractor early.

The Molex OSP PE Single Jacket Armour Gel 96F gives a robust, high-capacity singlemode backbone for routes that need to last. For the exact dimensions, ratings and installation limits, refer to the manufacturer datasheet, and have the cable installed and tested by a qualified fibre technician.

SKU CFR-00900 Category Brand:

MOLEX
OSP PE Single Jacket Armour Gel 96F

Molex
OSP PE single jacket armoured singlemode fibre cable, 96 fibres
Outside plant fibre backbone and campus links

Share this on your favourite channel:

Sign Up & Register

Mustek’s Infrastructure Technology Team are one of the largest suppliers of infrastructure technology in the country and on the continent. Register to become a reseller. Already a reseller?

Sign up for the latest pricelists, specials and offers.

Are you registered as a reseller?*
Area of interest?*

UPS Q&A

Keep up to date with the latest product developments from our divisions and outstanding solutions that will inspire you.

UPS Configuration Questionnaire

Ready to talk