9PX Gen2 11000VA 11000W Rack/Tower UPS Netpack

Eaton
9PX Gen2 UPS, 11000 VA / 11000 W, hardwired input, 4U rack/tower
Outputs: 8x C13, 8x C39

Eaton 9PX Gen2 11000 VA Rack/Tower UPS Netpack

The Eaton 9PX Gen2 11000 VA Netpack is a high-capacity online UPS for businesses that cannot afford unplanned downtime. Online double-conversion UPS units keep the connected equipment supplied from clean, regulated power at all times, so the load is protected from brownouts, spikes and mains interruptions.

With a capacity of 11000 VA and 11000 W, this Netpack is intended for larger racks of servers, storage arrays, switches and routers. Its 4U form factor makes it compact for the power it delivers, and it can be mounted in a 19-inch cabinet or set up as a tower where rack space is not available.

Key features

  • Rated 11000 VA / 11000 W
  • Hardwired input for direct connection to the supply
  • Eight C13 and eight C39 outlets
  • 4U rack or tower format
  • Gigabit network card included for remote monitoring
  • Rack-mounting kit included
  • Supports up to four 9PXEBM240RT3UG2 external battery modules

Power and outlets

The hardwired input means the unit is fixed to the building supply, which is common for higher-rated UPS systems. The eight C13 outlets suit most standard server and network power cords, while the eight C39 outlets provide higher-current connections for heavier loads. Planning the load across both outlet types helps keep each circuit within its rating.

Network management

The included Gigabit network card lets facilities staff check UPS status, battery condition and events over the network. This allows automatic shutdown of connected servers during an extended outage, protecting data that would otherwise be lost.

Extending runtime

Runtime depends on the connected load and the battery configuration. The 9PX Gen2 can be expanded with up to four 9PXEBM240RT3UG2 external battery modules, which are sold separately. Adding batteries lets the system ride through longer outages or provide more time for orderly shutdown.

Typical uses

  • Server rooms and comms rooms
  • Small data centres
  • Network and storage equipment racks
  • Point-of-sale and business IT systems that need continuous power

Installation notes

Because the input is hardwired, installation should be carried out by a qualified electrician. Start-up and commissioning services for installations outside South Africa should be arranged through the Eaton sales representative. Confirm the rack space, cabling and battery requirements before ordering so that the complete system is correctly specified.

Eaton
9PX Gen2 11000VA 11000W Rack/Tower UPS Netpack

Eaton
9PX Gen2 UPS, 11000 VA / 11000 W, hardwired input, 4U rack/tower
Outputs: 8x C13, 8x C39

Share this on your favourite channel:

Sign Up & Register

Mustek’s Infrastructure Technology Team are one of the largest suppliers of infrastructure technology in the country and on the continent. Register to become a reseller. Already a reseller?

Sign up for the latest pricelists, specials and offers.

Are you registered as a reseller?*
Area of interest?*

UPS Q&A

Keep up to date with the latest product developments from our divisions and outstanding solutions that will inspire you.

UPS Configuration Questionnaire

Ready to talk