INFRASTRUCTURE TEAM
+27 (0) 11 237 1000
Molex
24 core multimode OM3 fibre optic cable, loose tube, PE insulated
Suitable for interior and exterior use, black
The Molex CFR-00797 is a 24 core multimode OM3 fibre optic cable designed for structured cabling backbones. It combines a loose tube fibre arrangement with a black PE insulated outer sheath, and it is listed for both interior and exterior use. It is a bulk cable intended to be installed, terminated and tested by a qualified cabling installer.
Structured fibre backbones carry many links on a single cable run. A 24 core cable gives a network designer a large number of fibres in one route, so fewer cable pulls are needed between distribution points. The cable sits in the Molex datasheet range for multimode fibre, which is part of the wider Molex copper and fibre structured-cabling system.
In a loose tube cable, the fibres are held inside protective tubes that are separated from the outer jacket. This arrangement gives the fibres room to move with temperature changes and cable handling, which helps protect them during installation. It also makes the fibres easier to separate, identify and route when they reach a splice box, fibre panel or termination enclosure. For larger cables such as this 24 core unit, clear grouping of tubes and fibres is useful when records are kept for a network.
Multimode fibre has a larger core than singlemode fibre and is designed for shorter and medium distance links in buildings, campuses and data centres. OM3 is a multimode grade that is commonly specified for network equipment using multimode optical transceivers. When choosing a fibre grade, the installer should confirm that the active equipment, transceivers and patch leads match the same multimode type, so that the links work as designed.
The Int/Ext description means the cable is intended for use both inside buildings and outside them. A cable that runs from one building to another, or from an external duct into a comms room, can use the same product. The installer should still follow the approved installation method for the site, including any requirements for entry points, bends, support and protection along the route. The PE sheath is a polyethylene outer layer, which is the type of jacket commonly used where the cable must be protected from the environment along its route.
Because this is a 24 core bulk cable, it is normally cut to length on site, prepared and terminated into splice trays, cassettes or fibre panels. Work should be done with suitable fibre tools and clean termination practice, and each core should be tested after installation. Keep cable bend radius within the limits given by the manufacturer and avoid pulling the cable beyond its rated tension. Label both ends of each tube and core so the network can be documented correctly.
This cable suits installers, network contractors and IT departments who are building or extending a structured multimode fibre network. It is most useful where many fibre pairs must be run in one route, and where the cable will be terminated into a Molex or compatible fibre enclosure system. If the project requires a specific jacket rating, flame classification or length, please confirm these details with the supplier before ordering.
Molex
24 core multimode OM3 fibre optic cable, loose tube, PE insulated
Suitable for interior and exterior use, black
Share this on your favourite channel: